IRAS Explanatory Supplement
VI. Flux Reconstruction and Calibration
B. Determination of Relative Flux
Chapter Contents
| Introduction | Authors
| References
Table of Contents |
Index | Previous Section
| Next Section
- Overall Procedure to Determine Relative Photometry
- Photometry of Point Sources and Small Extended Sources
- Photometry of Extended Emission
- Determination of F[TFPR]
- Determination of the TFPR Annual Variation
- Problems
- Rejected Internal Reference Source Flashes
- Radiation
- Photon Induced Responsivity Enhancement
- Point Sources
- Extended Emission
- Variation of Frequency Response with Total Flux
The processing outlined above resulted in a current which was assumed
to be proportional to the flux incident on the detector except for small
effects due to the dwell time on a source. The conversion of the current
to relative flux was effected by a comparison of source amplitudes with
amplitudes resulting from flashes from the internal reference source (see
Section II.C.3) which provided a secondary
relative calibration source. The internal reference source was in turn
absolutely calibrated with respect to celestial sources using NGC 6543
as a secondary transfer standard; see Section VI.C
below. The processing to obtain the relative photometry of the IRAS sources
is discussed in this section.